4
Maintenance and service
50
Apply Loctite
®
243
™
thread locker to clean screw threads before installation.
Installing the gear chamber and center plate to pump housing
1.
Align the pump housing with the gear chamber. Be sure that the alignment pin of the pump housing and center
plate is properly engaged, Figure 1
2.
Using a 10 mm hex key, install the eight hex socket screws and tighten to 468 in-lb (70.0 Nm), Figure 2.
See Figure 3 for the double-pass tightening sequence of the pump housing screws.
Liquiflo FTS Transfer Pump User Manual
Series No. FTS400
Figure 2
Figure 1
Figure 3
6
2
3
4
5
1
7
8