Replace wiper blades and springs as an entire set.
1.
Position the arms of the first spring in the cutout on the bottom of the wiper blade, Figure 1.
2.
Slide the spring and wiper blade into the wiper blade slot, compressing the spring to ease it and the wiper blade half
the way into the wiper-blade slot, Figure 2.
3.
Position the second spring in the wiper-blade cutout, compress it, Figure 3.
4.
Slide the wiper blade and compressed spring into the wiper-blade slot until it stops, Figure 4.
5.
Repeat step 1 through 4 above on the remaining new wiper blades to replace the whole set.
Installing the wiper blades
Figure 3
Figure 1
Figure 4
Spring arms up into
blade channel
Figure 2