4
Maintenance and service
Liquiflo FTS Transfer Pump User Manual
Series No. FTS400
19
Removing gear chamber and center plate from pump chamber housing
1.
Using a 10 mm hex key, remove the eight M12 x 55 mm socket head cap screw fasteners that attach the gear
chamber and center plate to the pump housing, Figure 1.
2.
Carefully pull the gear chamber sub assembly to remove it from the pump chamber, Figure 2.
3.
If the gear chamber assembly sticks to the pump chamber, use the 2x M12 threaded holes for jacking out or the 2x
pry slots on the center plate, Figure 3
Figure 1
Figure 2
Figure 3
Jacking screw hole
Prying slot