4
Maintenance and service
Liquiflo FTS Transfer Pump User Manual
Series No. FTS400
26
Removing pump housing from volute housing
NOTE: Early versions used socket head cap screws. Later versions switched to hex head bolts.
1.
Using a 10 mm hex key or 19 mm wrench as appropriate, remove the eight M12 x 45 mm fasteners holding the
pump housing to the volute housing, Figure 1.
NOTE: The O-ring inside the suction elbow will resist separation of the pump chamber and volute housing.
2.
To break the seal between the pump chamber and volute housing, insert a prying tool between the pump chamber
and volute housing and pry until the seal releases, Figure 2. Alternately, a rubber mallet striking the elbow cup will
help separate the two pieces.
3.
Stand pump up vertically and Lift the pump chamber off to expose the volute housing, Figure 2.
Figure 1
Figure 2