4
Maintenance and service
Liquiflo FTS Transfer Pump User Manual
Series No. FTS400
29
Replacing center plate inner seals and needle bearings
1.
Using a 3 mm hex key, remove the six M4 x 20 mm socket head cap screws from the face plate, Figure 1.
2.
Lift the face plate off the center plate, Figure 2. Use pry points if necessary.
3.
Remove the center plate inner shaft seals using a seal removal tool, hooking it under the lip of each seal and gently
prying upward, Figure 3.
Continued on next page
Lubricate the inner lips of the shaft seals with Mobilgrease XHP
™
222.
Figure 2
Figure 3
Seals
Figure 1
Six M4x20 screws