- 5 -
Dip Switch Configuration
•
In order to accommodate as many units as possible, there
is a set of four small “dip switches” on the control board
that must be configured. Refer to the following table and
figure for the required configuration for your RV.
NOTE: If any of the blank configurations are used (noted by
“DEAD POSITION) in the table below), the Controller will not
work. In this case, the Control Pad Leveler position LEDs will
flash up and down.
Configurations
Rear Levelers
Rear Levelers Stroke Length
Front Levelers
Front Levelers Stroke Length
0000
7.5K
15" of travel
5K Direct Drive
24" of travel
0001
7.5K
13" of travel
5K Direct Drive
24" of travel
0010
DEAD POSITION
0011
DEAD POSITION
0100
DEAD POSITION
0101
DEAD POSITION
0110
DEAD POSITION
0111
DEAD POSITION
1000
DEAD POSITION
1001
DEAD POSITION
1010
DEAD POSITION
1011
DEAD POSITION
1100
DEAD POSITION
1101
DEAD POSITION
1110
DEAD POSITION
1111
DEAD POSITION
NOTE: These switches MUST be configured correctly. Incorrect configuration can result in
poor performance or damage to the system.
Summary of Contents for Levelegs