- 18 -
This guide is only intended for use on Atwood products by service technicians who have successfully
completed Atwood training. This guide should be used in conjunction with the appropriate Instruction
Manual provided with the product and any applicable Industry Standards. This is not intended to be a
complete list.
NOTE: The noise of the levelers will vary with the different loading situations of
the RV. A change in noise alone is not an indicator of an issue.
KEY PAD WILL NOT TURN ON
•
No power to key pad
1. Insure Activation Switch is flipped to the ON position.
2. Check wiring between keypad and control board.
3. Turn off Activation Switch, disconnect power on the control board (labeled P1 VBATT, towards
the front of the RV) for one minute and then reconnect. Make sure to connect power before
turning on Activation Switch.
SCROLLING LIGHTS ON KEYPAD
•
Communication between keypad and control board lost.
Check wiring between keypad and control board.
RED AND GREEN LIGHTS COME ON FOR LEVELERS DURING INSTALL PROCEDURE
•
Incorrect wiring
1.
Press EXT and the two directional buttons (e.g. DRIVE and FRONT) that make up the position
of that leveler. If the leveler moves for about 0.25-0.5 seconds and then stops, the wiring
could be incorrect.
a.
Check that the correct leveler moves when EXT and the two directional buttons that make
up the position of that leveler are pressed.
2.
Check that the power wires for the levelers are connected to the correct terminals on the
control board.
3.
Check that all of the SENSOR CONNECTOR wires are connected to the corresponding motor
at each of the leveler locations.