- 19 -
LEVELER CONTINUES TO “CLUTCH”
•
Leveler replaced or operated separate from control pad (manually operating nut / drive shaft or
supplying direct power to the leveler)
•
If the system does not beep an “error mode”
1. Put system in error mode by disconnecting one leveler from power and pressing either RET or
EXT and FRONT or REAR for the corresponding leveler.
NOTE:
The attempted operation must require the disconnected leveler to function through the
board.
2. Reconnect leveler to power.
3. Confirm all levelers are extended a minimum of 2” from their fully retracted position. If
necessary manually extend all levelers by either:
a. Simultaneously pressing the EXT button and the two directional buttons (e.g. DRIVE and
FRONT) that make up the position of a single leveler.
b. Simultaneously pressing the EXT button and one directional button in order to move the
two levelers on that side.
NOTE:
Levelers will stop moving if a button is released.
4. Listen to insure all levelers move when manually activated.
5. Hook the RV to the tow vehicle.
6. Press RET and ALL to retract all levelers.
•
If the system beeps an “error mode”
1. Press ON/OFF button. This will shut the warning alarm off and turn the system back on.
2. Make sure all levelers are at least 2” extended from full retraction. Manually extend the
levelers as shown in step 3 above if they are not.
3. Continue from step 4 above. Wait until all four leveler indicator LEDs are solid green. The
system is now out of error mode and ready for normal operations.
RED AND GREEN LIGHTS COME ON FOR A SPECIFIC LEVELER LOCATION
•
Loss of power or signal to leveler
1. Manually extend the individual leveler by holding down the EXT button and the two directional
buttons that make up the location of that leveler. Listen to insure all levelers move when
manually activated.
2. If leveler moves continue to step 3. If leveler does not move check the fuse for that location at
the control board. Replace fuse with Littelfuse Series 299 MAXI® Slo-Blo® 32VDC, 35 ampere
Automotive Blade Fuse or equivalent.
3. Hook the RV to the tow vehicle.
4. Press RET and ALL to retract all levelers.
5. If levelers do not move, inspect leveler power wiring at levelers and at control board to insure
proper connection.
6. If levelers briefly move (0.5 seconds) and then stop, inspect leveler sensor wiring at levelers
(smaller wires) at the motor and at the control board to insure proper connection.
ALL VERTICAL SIGNAL LIGHTS BLINK ON AND OFF
•
Nine cycle protection: If nine RET and ALL sequences are completed within 30 minutes, the
system will lock out for 15 minutes. To resolve, either:
a. Wait 15 minutes until the system becomes unlocked, or
b. Turn the activation switch off and disconnect power from the control board for one minute,
then reconnect power and turn activation switch ON.
KEY PAD SIGNAL IS ITERMITTENT
•
Check the connection of the activation switch at both the power connection, and six pin connector.