Rev:11.08.19
Page 73
CCD-0001573-08
Zero Point Calibration
The “Zero Point” is the programmed point that the trailer will return to each time the Auto Level feature is
used. Zero Point must be programmed prior to using the Auto Level feature to ensure the proper operation
of the leveling system. The Zero Point feature is only available on the OneControl Touch Panel leveling
system.
NOTE:
Prior to starting this procedure, double check all connections on the controller, jacks and touch
panel.
NOTE:
When calibrating Zero Point, the user has full manual control over the jacks. See “Basic Jack
Operation In Manual Mode in the "Operation - OneControl Touch Panel" section to adjust to the
desired level position. Press the "Enter" (Fig. 4H) button to set.
Setting the Zero Point
NOTE:
The following procedure works from Standard Mode only. See "Basic Jack Operation In Standard
Mode" in the "Operation - OneControl Touch Panel" section.
1.
Press the “CONNECTED” icon (Fig. 32A) at the top of the leveling screen, quickly six times. Wait a few
seconds until the gear icon with "OPTIONS" appears (Fig. 33A).
2.
Press the gear icon with "options" (Fig. 33A).
3.
The screen will show "SET UP: Zero Mode, Press Enter" (Fig. 34).
4.
Press the “Enter" button (Fig. 34A).
5.
The touch panel will present options for further leveling of the trailer, if needed. The screen will also
state "ZERO POINT CALIBRATION. Press Enter to set" (Fig. 35).
6.
Press "Enter" (Fig. 35A).
7.
Screen will show "Zero point stability check. Please wait..." (Fig. 36), followed by "Zero point set!"
(Fig. 37).
A
A
A
A
Fig. 32
Fig. 33
Fig. 34
Fig. 35
Fig.36
Fig. 37