TME-104-CLR-86DX-R0V2.doc
Rev. 0.2
12(
44
)
2.4
Hardware Setup
Caution
Be sure to observe the EMC security measures. Make sure you are always at the
same potential as the module.
Caution
Never connect or disconnect peripherals like HDD-, PCI- and ISA- devices while
the board's power supply is connected and switched on!
Use the cable set and the Mini-PCI-VGA card provided by LiPPERT to connect the Cool LiteRunner-86DX to a
VGA monitor. Connect PS/2 or USB keyboard and mouse, respectively. Use the 44-wire cable to connect the
harddisk. Make sure that the pins match their counterparts correctly and are not twisted! If you plan to use
additional other peripherals, now is the time to connect them, too.
Set the “Jumper Battery” that it has contact with both pins. The location can be found on chapter 2.2.
Connect a 5 volt power supply to the power connector and switch the power on.
Note In continuous mode there are not more than 1.2 amps necessary, but at power on
there are approximately t.b.d. A needed for a short time. That energy should be
supplied for this moment.
The value can increase with additions peripherals.
The display shows the BIOS messages. If you want to change the standard BIOS settings, press the <Del> key to
enter the BIOS menu. See chapter 4.3 for setup details.
If you need to load the BIOS default values, they can be automatically loaded at boot time. See chapter 4.3 how to
do it.
The Cool LiteRunner-86DX boots from CD drive, MicroSD, soldered flash, Compact Flash, USB floppy, USB stick,
or harddisk. Provided that any of these is connected and contains a valid operating system image, the display
then shows the boot screen of your operating system.
The Cool LiteRunner-86DX does not need any cooling measures, neither at standard environment temperatures
from 0 °C … +60 °C.