6. Preparation
Make sure that the unit is in perfect working order and that all
safety devices are in place!
Check the oil level in the angular gear! (See chapter "10.
Maintenance")
Check the lubrication in the chain drive! Run the machine for a
short time, in order to distribute the grease evenly. (See chapter
"10. Maintenance")
Check whether all screws are tightened, especially important are
the screws of the cutter blades and the drive flange!
Lubricate overload coupling (star ratchet Fig. 3) and universal
joint shaft of the drive prior to startup and then every 8 working
hours.
To do so, you must open the protective hood (Fig. 1 Ref. C).
Lubricating point:
Lubricating nipples (3x)
Star ratchet
Joint
Joint
Fig. 3