Restoring Factory Settings
This will restore all factory settings except for the language.
To restore factory settings:
-
Open the menu and go to the tab
“SETUP”.
-
Select
factory settings (4)
with the cursor.
-
Press the “ENTER” button. The display will show “READY” and the factory settings will
be restored.
-
Press “MENU” to leave the menu. The main screen will be displayed again.
DMX
The generator uses one DMX channel. The selected value of this channel defines how much
smoke is made:
DMX-value
Result
0
– 21
No smoke
22
– 178
Smoke, Smoke Density between 1% and 100%
179-255
Smoke Boost (20 second Boost, afterwards 100% density)
The DMX tab allows for DMX channel setting modifications, between 1 and 512. The generator
automatically recognizes a DMX controller. This does not necessitate manual intervention. To
avoid interference when using a wired remote control, the DMX can be disabled: DMX channel:
OFF.
To set the DMX channel up:
-
Open the menu and go to the DMX (1) tab.
-
Place the cursor on “DMX CHANNEL” (2).
-
P
ress the “ENTER” button. The chosen channel will start flashing.
-
Press the “UP” or “Down” button to modify this setting.
-
Press the “ENTER” button.
-
Press the “MENU” button to leave the menu. The main screen should be displayed
.