Manual Timer Program
1.
Menu
The menu shows all available tabs.
2.
Delay
As soon as the “RUN” button is pressed, the generator will wait
during the selected delay time before starting the program.
Set the delay to 0:00 to deactivate the delay.
3.
Mode
TIMER means Manual Timer Program
4.
Smoke Time
Set how long you want the generator to make smoke.
5.
Pause Time
Set how long the generator should wait after smoke production before
it starts again.
6.
Next Tab
Next tab is Setup.
7.
Repeat
Set if the program should repeat continuously or just once.
8.
Cursor
The cursor shows which menu item is active.
To adjust the Manual Timer Program:
-
Open the menu and go to the
tab program (1)
-
Set the
mode (3)
to
Timer
.
-
Set the
smoke time (4)
to the desired length of time.
o
Minimum is 1 second, maximum is 10 minutes.
-
Set the
delay (5)
to the desired length of time.
o
Minimum is 1 second, maximum is 10 minutes.
-
Set the
repeat function (7)
to on or off.
-
If a delay before the filling of the room with smoke is desired, insert it in
delay (2)
.
-
Push “MENU” to leave the menu. The main screen will be shown again.
-
Set the desired smoke density with the “UP” and “DOWN” buttons.
-
Press “RUN” to start the program.