3. Technical Data
Electrical connection
Mains:
400 V AC, 3 Ph, N, PE, 50 Hz
Connected power:
140 kVA / 200 A
Dimensions
useful chamber in mm (wxdxh):
430 x 680 x 450
useful volume (liter):
131
outer dimensions furnace in mm (wxdxh):
1200 x 2000 x 2350
outer dimensions with re-cooling unit:
in mm (wxdxh):
2300 x 2400 x 2650
outer dimensions of control unit:
in mm (wxdxh):
1200 x 600 x 2200
outer dimensions of cooling water recooler:
in mm (wxdxh):
730 x 730 x 1600
Temperatures
max. temperature in neutral atmosphere
(short time):
1500 °C
continuous temperature
in neutral atmosphere:
1500 °C
max. temperature in neutral atmosphere
with recirculation fan
(short time):
750 °C
relative temperature uniformity:
approx. ± 10°C and better in the
middle depending of the load and
the optimization of the control unit
Vacuum
max. Vacuum
< 1 mbar