Page 5 of 12
NTI AG / LinMot
2 CONNECTING TO THE CC_LINK IE FIELD BASIC NETWORK
2.1 PIN ASSIGNMENT OF THE CONNECTORS X17-X18
The CC-Link IE Field Basic connector is a standard RJ45 female connector with a pin assignment as defined
by EIA/TIA T568B:
X17 – X18
ETHERCAT Connector
Pin
Wire color code
Assignment 100BASE-
TX
1
2
3
4
5
6
7
8
case
WHT/ORG
ORG
WHT/GRN
BLU
WHT/BLU
GRN
WHT/BRN
BRN
-
Rx+
Rx-
Tx+
-
-
Tx-
-
-
-
RJ-45
Use standard patch cables (twisted pair, S/UTP, AWG26) for wiring. This type of
cable is usually referred to as a “Cat5e-Cable”.
2.2 SETTING THE STAION-ID / IP-ADDRESS
The lowest byte of the Station ID (192.168.3.x) can be set via the two Hex-Switches S1 and S2. This byte can
have a value between 1 (01h) and 254 (FEh). After changing the ID the new value gets active after a reset of the
device.
NodeID Selectors
C12x0
S1 (5..8)
S2 (1..4)
Station-ID High Nibble (0 … F). Bit 5 is the
LSB, bit 8 the MSB.
Station-ID Low Nibble (0 … F). Bit 1 is the
LSB, bit 4 the MSB.
Setting the Station-ID high & low to
0xFF initiates resetting the drive to
manufacturer settings!
3 CC-LINK IE FIELD BASIC PARAMETERS AND VARIABLES