Page 11 of 12
NTI AG / LinMot
6 INTERFACE ERROR CODES
Please refer to “Usermanual Motion Control Software” for the error codes of the MC software. The CC-Link IE
FB interface has the following additional error codes:
Error Code
Error Description
Recommended Actions
C0h
Cfg Err: Invalid StationID
The defined StationID is not in the valid
range.
7 TROUBLESHOOTING
7.1 ANALYZING TRAFFIC IN CC-LINK IE FIELD BASIC NETWORKS
To analyze the data traffic in a CC-Link IE Field Basic network the use of a network protocol analyzer is
strongly recommended.
Wireshark is one of the most used analyzers and can be downloaded free of charge from
7.2 FREQUENT PROBLEMS AND SOLUTIONS
Problem:
The drive cannot connect to the PLC
Possible Solution:
Check if the Station-ID / IP-Address of the drive matches with the one configured in the
PLC.
Possible Solution:
Check if the Station-ID / IP-Address of the drive is unique, and no other device in the
network has the same ID.