Installation Guide C1100
NTI AG / LinMot
0185-1062-E_6V12_IG_Drives_C1100
Page 11 of 29
7.3
X2/X3 Motor Connection
X2
Motor Phases
PH1+
PH1
PH2+
PH2-
PE/SCRN
LinMot Motor:
Motor Phase 1+ red
Motor Phase 1-
pink
Motor Phase 2+ blue
Motor Phase 2-
grey
Shield
3-phase EC-Motor:
Motor Phase U
red
Motor Phase V
pink
Motor Phase W
blue
(RR-)
Shield
Connector has to
be ordered
separately: see
chapter 14)
•
Use 60/75°C copper conductors only
•
Conductor cross-section: 0.5 – 2.5mm
2
(depends on Motor current) / AWG 21 -14
•
PH2- could be used as RR- with 3 phase Motors the other side of regeneration resistor has to be wired to PWR
X3
Motor Sensor / Brake
1
6
2
7
3
8
4
9
5
case
LinMot Motor:
Do not connect
Brake+
Do not connect
Do not connect
+5VDC
AGND
Sensor Sine
Sensor Cosine
Temp In
Shield
EC Motor:
Do not connect
Brake+
Do not connect
KTY
+5VDC
AGND
Sensor Sine / Hall Switch U
Sensor Cosine / Hall Switch V
Hall Switch W
Shield
DSUB-9 (f)
Note:
•
Use +5V (X3.3) and AGND (X3.8) only for motor internal hall sensor supply (max. 100mA).
•
The motor cable length must not exceed 30m.
•
Brake+: 24V / max.500mA, Peak 1.4A (will shut down if exceeded) the other terminal has to be wired to AGND
(X3.8)
Caution:
•
Do NOT connect AGND (X3.8) to ground or earth!
Temperature Sensor:
•
A resistive temperature sensor (PT1000, KTY) could be connected b5VDC (X3.3) and KTY (X3.7)
Important Notes:
•
Use Y-style motor cables only (for example K15-Y/C)! A W-style cable has a different shielding, so it cannot be modified to
a Y-style cable!
•
The motor cable length must not exceed 30m.
Summary of Contents for C1150-DS-XC-0S
Page 24: ...Installation Guide C1100 Page 24 of 29 0185 1062 E_6V12_IG_Drives_C1100 NTI AG LinMot ...
Page 25: ...Installation Guide C1100 NTI AG LinMot 0185 1062 E_6V12_IG_Drives_C1100 Page 25 of 29 ...
Page 26: ...Installation Guide C1100 Page 26 of 29 0185 1062 E_6V12_IG_Drives_C1100 NTI AG LinMot ...
Page 27: ...Installation Guide C1100 NTI AG LinMot 0185 1062 E_6V12_IG_Drives_C1100 Page 27 of 29 ...