Installation Guide C1100
NTI AG / LinMot
0185-1062-E_6V12_IG_Drives_C1100
Page 21 of 29
13
Safety notes for the installation according UL
Markings:
•
Wiring terminal markings:
See markings on the enclosure and the corresponding chapters in the installation guide!
•
Cautionary Marking:
See markings on the enclosure and the corresponding chapters in the installation guide!
•
Motor overload protection must be provided externally in the end-use. Motor Overload protection can
alternatively be provided when the connected motor has a thermal sensor rated 5V DC, max. 100mA
which is connected to the drive thermal sensor input (X3). (The LinMot P01-Motors are therefore
protected by the drive)
•
The transients have to be limited to max. 0.8kV on the line side of the drive.
•
The 24VDC supply for the control circuit must be protected with an external UL Listed 3A DC Fuse.
•
Proposed ratings, to be evaluated in the end-use:
•
Input Voltage:
72VDC
•
Input current:
15A
•
Output Voltage:
61.5V rms
•
Output Current:
17.7A rms max.
•
Number of Phases:
2 by 1 Phase
•
Frequency range:
0-500Hz
•
Duty cycle rating:
10%
•
Relays (only for -1S variant):
•
Rated Contacts:
max. 24VDC 6A.
•
Coil:
24VDC
•
Surrounding air temp:
max. 85°C
•
Control Power (X4-2):
24VDC (Protected with an external UL Listed 3A DC Fuse)
•
Surrounding Air Temperature: max. 50°C
•
A separate 24VDC power supply protected with an external UL Listed 3A DC Fuse connected to
the output of the power supply must be used to protect the secondary control circuit (safety
relays on X33)
Summary of Contents for C1150-DS-XC-0S
Page 24: ...Installation Guide C1100 Page 24 of 29 0185 1062 E_6V12_IG_Drives_C1100 NTI AG LinMot ...
Page 25: ...Installation Guide C1100 NTI AG LinMot 0185 1062 E_6V12_IG_Drives_C1100 Page 25 of 29 ...
Page 26: ...Installation Guide C1100 Page 26 of 29 0185 1062 E_6V12_IG_Drives_C1100 NTI AG LinMot ...
Page 27: ...Installation Guide C1100 NTI AG LinMot 0185 1062 E_6V12_IG_Drives_C1100 Page 27 of 29 ...