Installation Guide C1100
Page 10 of 29
0185-1062-E_6V12_IG_Drives_C1100
NTI AG / LinMot
7
Description of the connectors / Interfaces
7.1
PE
PE
Protective Earth
PE
•
Use min. 4mm
2
(AWG11)
•
Tightening torque: 2Nm (18 lbin)
7.2
X1
X1
Motor Supply
PWR
PGND
Connector has to
be ordered
separately: see
chapter 14)
Motor Supply: 72VDC nominal, 24...85VDC
Absolute max. Rating: 72VDC +20%.
External Fuse: 16A slow blow / min. 100VDC
If motor supply voltage exceeds 90VDC, the drive will go into error state.
•
Use 60/75
°
C copper conductors only
•
Conductor Cross-Section 2.5mm
2
(AWG14) max Length 3m