Torchmate 5100
70
Basic Troubleshooting
Machine Faults:
Problem
Solution
"Please Enable The Drives" Error Message
Appears
Release BOTH Emergency Stops buttons and press the
green "ENABLE" button.
Following Error (AXIS ID)
Push the red Emergency stop button, move the gantry or
axis to clear the obstruction, release the Emergency stop
button and enable the drives.
Datum the machine.
Drive Fault (AXIS ID)
Push the red Emergency stop button. Release the
Emergency stop button and enable the drives. Datum the
machine. If the error message persists and the axis ID is
X, Y, U, or Z, check Fuse #1 in the electrical cabinet. If the
axis is W or V check Fuse #2 in the electrical cabinet.
When the machine is turned on, the computer
and monitor do not power on
Check power at the supply side. Verify breakers and any
GFCI outlets. Check Fuse #4 in the electrical cabinet.
The water level does not adjust when clicking
the Up/Down button on the main screen
Restore Shop Air to the tables manifold.
None of the downdraft doors operate during a
cut
Restore Shop Air to the tables manifold.
The bevel motors make a light humming noise
The motors apply power to hold their position in normal
operation. This will be heard as an audible hum.
Accumove Controller Connecting Screen
If this screen is displayed for longer than 1 minute, turn
off power to the machine for 1 minute. Turn the power
back on. If the same condition exists, check Fuse #3 inside
the electrical cabinet.