The FlexCut 125 will have two barrel connectors to attach to the bulkhead. When moving your FlexCut 125, use
a team lift or hoist. A 10 ft (3m) power cord is provided with the FlexCut 125. Three Phase Input Only. Connect
green lead to ground per National Electric Code.
For further information, please reference the FlexCut 125 user guide - IM10300.
Unpacking: FlexCut 125
Connect black, red and white leads to power. In
all cases, the green or green/yellow grounding
wire must be connected to the grounding pin
of the plug, usually identified by a green screw.
Attachment plugs must comply with the Standard
for Attachment Plugs and Receptacles, UL498.
The product is considered acceptable for use only
when an attachment plug as specified is properly
attached to the supply cord.
GROUND CONNECTION
CONNECT GROUND LEAD PER LOCAL
AND NATIONAL ELECTRIC CODE
INPUT CORD STRAIN RELIEF
ROUTE INPUT CORD THROUGH RELIEF
AND TWIST NUT TO TIGHTEN
POWER CONNECTION BLOCK
CONNECT EACH PHASE OF A
THREE PHASE CONDUCTOR HERE
P1
PLASMA
INTERFACE
P2
RESERVED
P3
CAN
INTERFACE
P4
AUXILARY
I/O
POWER
ENTRY
ETH 1
FLEXNET
ETH 0
EXT. NETWORK
Star Ground
Star Ground
FRONT
VIEW
BOTTOM
VIEW
120v Connection
CNC Interface
Cable
3-ph
Main Power
Air or Gas Inlet (1/4”
Female Quick Connect)
from bulkhead:
Torch Lead
Main Power
Switch
Work (ground)
Connection to
Star
FlexCut 125
Front
FlexCut 125
Back