Site Preparation - HD
Locate power supply
within 6’ of table cable
chain.
167”
Load From
This Side
15’ Power Cord, Nema 5-15P
Shop Air Supply
Earth Ground
(provided by customer)
5100 HD
Gases
(provided by customer)
p
laced within 15’ of FineLine
Incoming AC power
for plasma cutter,
shop air supply, and
termination of gas
hoses from supply
FineLine
Power
Supply
14” Duct, Downdraft
Models Only
33”
37”
113.25”
Operator
Console
MAINTAIN WORK AREA
Lincoln Electric FineLine® High Definition Power Supplies have a larger power box and a gas controller to mix
several different types of gases utilized in HD plasma cutting. The placement of these products with the 5100
must be within 6’ of the cable chain’s end. This also determines the location of incoming power to the FineLine
plasma cutter, and the termination of gas leads to the plasma cutter.
The FineLine plasma cutting system requires a minimum of 100% oxygen source, 100% nitrogen source,
and shop air for steel and aluminum cutting. Consult the FineLine users manual for gas pressure and volume
requirements.