F - MAINTENANCE
8695 4985 / C
F-26
ESSENTIAL OXYCUTTING
We recommend replacing the pipes
-
at the first sign of fatigue, wear and tear or damage
-
no later than after every 3 years by the user in case of heavy-duty use,
-
no later than after every 5 years in all other cases.
We recommend replacing the flame arrester non-returns:
-
As soon as flame return occurs
-
No later than after three years of use.
Caution:
Follow the rules below if a pipe or valves are replaced:
-
Use the spare parts recommended in this documentation.
-
The pipes are standardised (colour, composition); they
must be replaced by identical pipes. Gas pipes MAY NOT
BE REPAIRED.
-
The fittings must be changed, as they may be damaged
while changing the pipes.
-
Fittings must be degreased and cleaned of dust before
assembly: risk of explosion.
-
To change a valve on the unit, first take the line off its
support, then take the valve off the line.
-
Olive type fittings are screwed on directly.
-
Adhesive must be applied on other fittings and valves.
The adhesive must be compatible with oxygen. Risk of
explosion.
-
If acetylene is being used, tighten the fittings to
standardised torque according to the diameter (please
contact us). Risk of leaks and fire.
-
The pipes in the cable drag chains many not be under
strain, as that could lead to premature wear.
-
A leak test (e.g. with 1000 bulles bubble leakage tester)
must be carried out after each repair operation. Risk of
explosion.
Caution:
Whenever a flame arrester non-return is faulty, it must be
replaced. No cutting without anti-return. Risk of explosion and
fire.
Summary of Contents for ESSENTIAL OXYCUTTING
Page 6: ...A IDENTIFICATION 8695 4985 C A 2 ESSENTIAL OXYCUTTING ...
Page 12: ...B SAFETY INSTRUCTIONS 8695 4985 C B 8 ESSENTIAL OXYCUTTING ...
Page 20: ...C DESCRIPTION 8695 4985 C C 16 ESSENTIAL OXYCUTTING ...
Page 24: ...D MONTAGE INSTALLATION 8695 4985 C D 20 ESSENTIAL OXYCUTTING ...
Page 28: ...E OPERATOR MANUAL 8695 4985 D E 24 ESSENTIAL OXYCUTTING ...