D - MONTAGE INSTALLATION
8695 4985 / C
D-18
ESSENTIAL OXYCUTTING
The outputs are stated for one gas assembly and are to be multiplied depending on the number of gas assemblies.
GAS SUPPLY
The client should provide and install an isolating
device on each source. These devices must be
clearly identified and lockable..
The client should provide one Oxygen source
fitted with a regulator capable of delivering the
recommended flowrates and pressures.
Maximum Pressure
9 Bar
for oxygen.
Oxygen purity must be at least 99,5%.
Gas
Supply at the entry to the machine
Use
Nature
P in bars
+/-10%
Max. output in m³ / h
for X torches
1
2
3
4
mm
200
80
60
50
M
AC
H OX
Y
Cutting
Oxygen
8.2
22
23.5
23.5
26
Heating
Oxidants
Oxygen
Fuel
Acetylene
1.4
0.85
0.85
1.05
1.4
Propane
1.8
0.6
0.6
1
1.3
M
AC
H HP
Cutting
Oxygen
8.2
22
23.5
23.5
26
Heating
Oxidants
Oxygen
Fuel
Acetylene
1.4
0.85
0.85
1.05
1.4
Propane
1.8
0.6
0.6
1
1.3
1.2
LAYOUT OF CABLES AND FLEXIBLE PIPES
The customer should provide the means for supporting and keeping away from mechanical, chemical, or thermal
damage, the cables and flexible pipes from their source to the entry of the cable support chain
There must be no fitting inside technical gutters, as gas could build up in the gutter in the event of a leak.
Summary of Contents for ESSENTIAL OXYCUTTING
Page 6: ...A IDENTIFICATION 8695 4985 C A 2 ESSENTIAL OXYCUTTING ...
Page 12: ...B SAFETY INSTRUCTIONS 8695 4985 C B 8 ESSENTIAL OXYCUTTING ...
Page 20: ...C DESCRIPTION 8695 4985 C C 16 ESSENTIAL OXYCUTTING ...
Page 24: ...D MONTAGE INSTALLATION 8695 4985 C D 20 ESSENTIAL OXYCUTTING ...
Page 28: ...E OPERATOR MANUAL 8695 4985 D E 24 ESSENTIAL OXYCUTTING ...