SET-UP FEATURES MENU
The Setup Menu gives access to the set-up configuration. Stored in the set-up configuration are user parameters
that generally need to be set only at installation. The parameters are grouped as follows:
To access the set-up menu, press the right and left buttons of the MSP4 panel simultaneously. Note that the set-
up menu cannot be accessed if the system is welding, or if there is a fault (The status LED is not solid green).
Change the value of the blinking parameter by rotating the SET knob.
To exit the set-up menu at any time, press the right and left buttons of the MSP4 panel simultaneously. Alternately,
1 minute of inactivity will also exit the set-up menu.
PARAMETER
P.1
through
P.99
P.101
through
P.199
P.501
through
P.599
DEFINITION
Unsecured Parameters (always adjustable)
Diagnostic Parameters (always read only)
Secured Parameters (only accessible with Weld Manager)
PARAMETER
DEFINITION
P.0
Press the left button to exit the set-up menu.
P.1
WFS units
Metric = m/min wire feed speed units
English = in/min wire feed speed units (default)
P.2
Arc Display Mode
Amps = The left display shows Amperage while welding. (default)
WFS = The left display shows Wire Feed Speed while welding.
P.3
Display Options
This setup parameter was previously named "Display Energy"
If the previous software revision had this parameter set to display energy, that selection will
remain.
This option selects the information displayed on the alphanumeric displays while welding. Not
all P.3 selections will be available on all machines. In order for each selection to be included
in the list, the power source must support that feature. A software update of the power source
may be needed to include the features.
Standard Display = The lower displays will continue to show preset information during and
after a weld (default).
Show Energy = Energy is displayed, along with time in HH:MM:SS format.
Show Weld Score = The accumulative weld score result is shown.
P.12
Travel Options
This menu is used to change the travel options for a travel carriage, including wheel size and
starting and ending functions. Press the right MSP4 button to enter the Travel Options menu
and rotate the encoder to select either wheel size, starting or ending options. Press the right
MSP4 button to select the option. Press the left MSP4 button to set the value and exit. Rotate
the encoder to select other options, or press the left MSP4 button to exit the menu.
Travel Start Options
Start Button = Travel begins with the start button (default)
Arc Strike = Travel beings with arc strike.
Travel End Options
Stop Button = Travel ends with the stop button. (default)
Arc Out = Travel ends when the arc extinguishes.
Wheel Size
default value = 6.0”
wheel size for track welding = 5.65”
range = 3.0” to 12.0”
B-10
OPERATION
CRUISER
TM