To set limits, press the desired memory button 1-8 and
hold for 5 seconds. Release the memory button when
the LED begins to blink rapidly and the MSP4 displays
"Memory X Set Limits" as shown below.
SETUP will illuminate on the MSP4 panel and the dis-
play will show the following:
Four items show on the MSP4 panel.
• Memory Value
• High Limit
• Low Limit
• Parameter Name
One of these items will flash to indicate which item will
change when the MSP4 encoder is rotated. Press the
right button on the MSP4 panel to select the item to
change.
The Limits Setup menu shows a list of all parameters
available for the weld mode stored in the memory cho-
sen
To lock a parameter to a specific value that cannot
be changed, set the high and low limits to the same
value.
The memory value must always be less than or equal
to the high limit, and greater than or equal to the low
limit.
After setting limits, press the memory button with the
flashing LED. The MSP4 will ask to save or discard the
limit changes just made. Press the left MSP4 for button
(YES) to save and enable the limits and exit. Press the
right MSP4 button (NO) to exit and leave limits
unchanged.
ENABLING/DISABLING LIMITS
Limits for each memory may be enabled or disabled by
pressing and holding the appropriate memory button
for 10 seconds. Release the memory button when the
MSP4 display shows the following:
FIGURE B.18 - MEMORY SET LIMITS
FIGURE B.19 - MEMORY SET LIMIT DISPLAY
LOW
LIMIT
PARAMETER
NAME
MEMORY
VALUE
HIGH
LIMIT
FIGURE B.20 - MSP4 PANEL
FIGURE B.21 - ENABLING LIMITS
FIGURE B.22 - ENABLE/DISABLE LIMITS
B-8
OPERATION
CRUISER