CABLE CONNECTIONS
WELD CABLE SIZES
Tabulated below are copper cable sizes recommended
for different currents and duty cycles. Lengths stipulat-
ed are the distance from the welder to work and back
to the welder again. Cable sizes are increased for
greater lengths primarily for the purpose of minimizing
cable drop.
** Tabled values are for operation at ambient temperatures of 40°C and below. Applications above 40°C may
require cables larger than recommended, or cables rated higher than 75°C.
FIGURE A.23 - WIRE DRIVE MOUNTING
RECOMMENDED CABLE SIZES (RUBBER COVERED COPPER - RATED 75°C)**
CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK
CABLES
Amperes
Percent
Duty
Cycle
0 to 50 Ft.
50 to 100 Ft.
100 to 150 Ft.
150 to 200 Ft.
200 to 250 Ft.
600
600
600
650
650
700
60
80
100
60
80
100
3/0
2-1/0
2-1/0
3/0
2-1/0
2-2/0
3/0
2-1/0
2-1/0
3/0
2-1/0
2-2/0
3/0
2-1/0
2-1/0
4/0
2-1/0
2-3/0
4/0
2-2/0
2-2/0
2-2/0
2-2/0
2-3/0
2-3/0
2-3/0
2-3/0
2-3/0
2-3/0
2-4/0
800
800
1000
80
100
80
3-1/0
2-3/0
2-4/0
3-1/0
2-3/0
2-4/0
3-1/0
2-3/0
2-4/0
2-3/0
2-3/0
2-4/0
2-4/0
2-4/0
4-2/0
1000
1200
1200
1500
1500
100
80
100
80
100
3-3/0
3-4/0
4-4/0
4-4/0
5-4/0
3-3/0
3-4/0
4-4/0
4-4/0
5-4/0
3-3/0
3-4/0
4-4/0
4-4/0
5-4/0
3-3/0
3-4/0
4-4/0
4-4/0
5-4/0
3-3/0
3-4/0
4-4/0
4-4/0
5-4/0
A-13