D-3
MAINTENANCE
•
Check fan motor blades for encrusted particles and
clean if necessary.
•
Inspect and clean control panel with a non-aggressive
detergent.
•
Check inlets and outlets for tears or wear.
CONTROL PANEL
•
Check for functionality of control panel fan.
•
Inspect and clean any buildup or dirt on fan blade
impellers in control panel.
REPLACING FILTER CARTRIDGES OR EMPTYING
DUSTBINS
Shut off the compressed air feed and empty the pressure tank
of air by opening the drain valve on the back of the unit.
NOTE: The power must always be switched off at the circuit-
breaker or by the line fuses. Protective gloves and mask should
always be worn.
Take necessary precautions so that you and your fellow
workers are not overexposed to particulate. Wear
suitable personal protection equipment, such as gloves,
respirator, eye glass and protective clothing when
Check with local waste management or local agency(ies)
collected certain types of particulate which local
disposed in accordance with federal, state and local
regulations - which could vary from state to state and
between local municipalities within the state.
Use protective gloves. If not carried out with the
necessary caution, may cause serious personal injury.
Use breathing protection. If not carried out with the
necessary caution, may cause serious personal injury.
•
Maintenance work and functional testing should be performed
regularly to TRGS 560 section 5, paragraph 9 and to TRGS 528.
•
During maintenance the machine must be deenergized and
secured against switching on again.
•
The maintenance area must be cleaned afterwards.
•
During maintenance work the working area must be adequately
ventilated; this can be achieved by provision of a mobile
ventilation unit.
•
During maintenance, appropriate personal protective equipment
should be worn. We recommend half-face breathing masks to
DIN EN 141/143, protection class P3.
•
of in accordance with statutory instructions, using the plastic
sack disposal system supplied.
WARNING
PRISM® SUSPEND 4000
INLET DAMPERS
Dampers are located inside the filter housing. For best
access, remove the front filters by following the
Replacing Filter Cartridge procedure.
•
Clean all visible dirt from damper surfaces. Use non-
oil based solvent if needed
•
Clean visible dirt from damper linkage and bearings.
Lubricate if necessary using a graphite based
lubricant.