INSTALLATION
PRISM® SUSPEND 4000
Step 7a – (HANGING MOUNT ONLY) - Hanging Mount To Typical Buildings
FIGURE A.7a
PRISM® SUSPEND 4000 can be hung from many roof
structures. Typical roof structures include:
1. Steel Bar Joist
2. Steel Wide Flange Beam
3. Steel Channel Beam
4. Light Gage Roof Purlin
WARNING!
• Existing building structure types and framing
considerations vary greatly from building to building,
therefore each installation of this unit (including but not
limited to the building structure, brackets, hardware and
any
other structural supports) shall be approved by a
structural
engineer licensed in the governing jurisdiction.
Subsequent
building alterations or addition of other nearby
high vibration
equipment may require follow up analysis by
the licensed
structural engineer. Unapproved installations
can result in
falling equipment leading to severe personnel
injury or
death.
• High seismic locations may require special reinforcement
and additional lateral support. Follow governing local
building codes for inspection requirements following any
significant event. Significant events include but are not
limited to seismic and other impacts to the unit or structural
mounts.
• Do not store other material on top of or hang anything
from unit.
• Do not allow personnel under unit during service and
maintenance procedures
NOTICE!
• Do not locate other heat generating equipment nearby
that could raise the ambient temperature around the unit
above the max rating stated in the Technical Specifications
section.
• For unit to meet designed operation efficiency, do not
allow other equipment to obstruct the free flow of air to the
side intakes and from the front fan exhaust.
• Refer to the maintenance section for recommended
procedures to ensure unit functionality and safety
throughout the life of the product. For most unit
maintenance procedures, ensure access to front and sides
of unit using OSHA approved access equipment.
WARNING!
Do not use corner brackets for
primary mounting support of
this unit. They are only
intended for hoisting unit during
installation and for secondary or
redundant support.
WARNING!
Do not operate without the side
intake pre-filters installed in
their housings. For maximum
protection, prevent sparks from
reaching within 3 feet of unit's
side intakes.
A-8