GENERAL DESCRIPTION
fan/filtration unit designed to hang from the roof or mount to a
wall. When multiple units are strategically located in a workspace,
they function in a push/pull manner to filter out suspended weld
fume from the air.
The fan pulls air with particulate through the filters. When
pressure over the filter reaches a preset point, the internal self
cleaning mechanism cleans the filter cartridges with compressed
air shots, resulting in particulate dropping into a dustbin below
the unit.
THE INTENDED PURPOSE
Extraction of fumes that are released in the course of using
welding equipment for cutting and joining non-alloy and alloy
steels, including highalloy chromium/nickel steels with a nickel
and chromium content of
≥
30%
TRANSPORT AND ERECTION
Instruct all persons whose presence is not
required to stay out of the hazard area
Do not stand under or next to the load when it is being
lifted up or set down
Transport the unit or erection components on the pallets
provided, and secure them against falling over or
slipping.
Transport them with a suitable pallet truck or forklift
truck
The PRISM® SUSPEND 4000 must be secured to the
roof or wall in a manner approved by a structural
engineer licensed in the governing jurisdiction.
•
The installer is responsible for following
federal, state and local safety codes and
regulations.
•
Before drilling, verify locations of existing
gas, water or electrical conduits.
Excluded Uses!
•
Welding fumes containing oil
•
Aluminum dust
•
Burning or incandescent materials
•
Cigarettes
•
Aggressive media
•
Water and moisture
•
Explosive gases and/or dust mixtures
•
Dusts with toxic characteristics other than welding
fumes
•
The installation of this product is exclusively reserved
to authorized, well-trained and qualified electrical and
mechanical contractors.
•
Inspect the product and check it for damage. Verify the
functioning of the safety features.
•
Electrical connection to be executed in accordance
with local requirements. Ensure compliance with the
EMC regulatory arrangements.
•
Check the working environment. Do not allow
unauthorized persons to enter the working
environment.
•
Protect the product against water and humidity.
•
Use common sense. Stay alert and keep your attention
to your work. Do not use the product when you are
•
Ensure the workspace is well-illuminated.
•
Never install the product over entrances and exits
which must be used for emergency services.
•
Make sure that the workshop, in the vicinity of the
•
The PRISM® SUSPEND 4000 must be secured to the
roof or wall in a manner approved by a structural
engineer licensed in the governing jurisdiction.
•
Air containing particles such as chromium, nickel,
beryllium, cadmium, lead etc., which is a health hazard,
should never be recycled. This air must always be
brought outside the working area.
SELECT SUITABLE LOCATION
• Do not place equipment near radiant heat sources.
Do not place in a confined space. Allow a minimum of 4 feet
of clearance around sides and front of machine at all times for
proper operation and maintenance requirements.
ENVIRONMENTAL AREA
Keep the machine inside and dry at all times.
ATTENTION
WARNING
ATTENTION
A-2
INSTALLATION
PRISM® SUSPEND 4000
The Prism® Suspend 4000 is an ambient zero footprint