INSTALLATION
PRISM® SUSPEND 4000
Step 12 – Remote Control Panel Installation
FIGURE A.12
1. Mount remote control panel at eye level and
within 21ft of the top of the unit after it is
installed.
2. Connect power cable to power terminal block
inside panel.
3. Connect 12 conductor cable from sensor box on
top of unit to lower terminal block inside panel
per the system wiring diagram at the end of this
manual.
4. Install 1/4" air tube that runs along 12 conductor
cable into fitting on bottom of panel.
Connect Power
Cord here
Connect 12 Conductor
Cable here (per system
connection diagram)
Connect 1/4" tube from
air regulator here
A-13