IT-GB-FR-ES
mod. 514S-514N
29/104
1
INSTALLATION
RESERVED TO INSTALLER
1.1
Normative and prescriptions
•
Read carefully the contents of this handbook, it contains important information and
instructions for installation, use, maintenance and product safety.
•
The appliance must be installed inside an environment considered suitable for
installation and use by competent authorities. All laws, standards and regulations in force
on the installation site must be observed, especially regarding fire prevention.
•
Technological connection and appliance installation must be carried out by qualify staff
authorized to release a conformity certificate according with the normative in force and
current standards.
•
All the normative concerning civil town planning and/or industrial in force must be
respected inside the environment of installation of the appliance.
•
All laws, standards and regulations in force on the installation site must be observed,
regarding: gas and flues, electricity, water and steam, drains and waste disposal, forced
ventilation/extraction, air intake and air conditioning. All the local and energy supplier
authorities prescriptions must be respected.
•
The installation must be carried out and certified according to the normative in force
regarding installations, exhaust fumes connections, electricity, water, ventilation /
suction.
•
The manufacturer disclaims all responsibility caused by no correct installation,
using, tampering, maintenance or no respect of normative in force.
1.2
Preliminary operations
•
Take away the packing
•
Before installation, check the appliance integrity. In case of doubt, do not use the
appliance and call the dealer.
•
Packing materials is for recycle, getting it in the specify container
1.3
Appliance positioning
•
The installation environment should have :
−
A suitable floor for stove weight and calorific radiation, otherwise preventive
measures should be adopted. (i.e. Plate for charge distribution ).
−
A suitable floor for stove calorific radiation to guarantee the building against any
fire risk.
−
The stove should be installed so that gas flue, chimney and cleaning could be easily
done.
−
A minimal distance from flammable materials ( Security Distances)
−
A suitable ventilation as normative in force.
FLOOR PROTECTION
•
The equipment must be installed on a non–combustible surface. In case of flammable
floor (as wood, moquette, etc.) is necessary to prepare a protective base of the floor
(sheet steel, ceramic or other) with the following dimensions:
−
Hold up in front ≥ 500
mm;
−
Hold up lateral ≥ 300
mm;
−
Hold up back
≥ 100
mm