IT-GB-FR-ES
mod. 514S-514N
50/104
Ash or soot out of the
stove.
−
The fire door is open
during combustion.
−
No seal between the
combustion fan and
exhaus gas.
−
Please to close the fire door when
the stove is lighting.
−
To seal every parts of exhaus
system and call the assistance
centre.
−
Ignition harness could ne checked
only with apparatus not electrical
connected.
−
Reparation has to be done by a
qualify staff.
ALARM SIGNAL ON CONTROL PANEL
Alarm Explication Possible reason
Remedy
ALAr
Hot
PEL
Pellet tank
temperature
is too high
(over the
consent).
−
Obstruction of top and
frontal air intake.
−
Temperature feeler breaking.
−
Breaking convection motor.
−
To check the air intake.
−
To substitute the feeler.
−
To check convection motor
functioning.
ALAr
no
Acc
The
combustible
doesn’t
inflame
during the
ignition
phase – No
fire bearing.
−
No Pellets feed.
−
Glow plug breaking
−
No fire bearing from fumes
feeler.
−
Pellets with ignition difficult.
−
To check Pellets tank level .
−
To check the screw feeder
function.
−
To check electrical connection.
−
To substitute the glow plug.
−
To check position, function and
electrical connection of
temperature fumes feeler.
−
To employ combustible of
good quality.
ALAr
no
ASP
Chimney
exhaust
fumes
blocked.
−
Chimney blocked.
−
Electrical connection break
off.
−
Pressure switch breaking.
−
To check the chimney.
−
To check electrical connection.
−
To substitute switch breaking.
ALAr
Sic
FAiL
Temperature
pellets tank
or tangential
fan too
higher.
−
Up and Front Air intake
obstruction.
−
Temperature thermostat
breaking.
−
Convection Motor breaking.
−
To check air intake.
−
To substitute thermostat.
−
To check convection motor
ALAr
deP
FAiL
Chimney
exhaust
fumes
blocked
−
Chimney blocked.
−
Electrical connection break
off
−
Pressure switch breaking .
−
Check the chimney.
−
Check electrical connection.
−
Substitute switch breaking.