IT-GB-FR-ES
mod. 514S-514N
45/104
COMBUSTION REGULATIONS
Sometimes changing the pellets, in sight of the several types of wood pellets presents on the
market, some modifications on equipment combustion could appear. An evident signal of a
wrong combustion is the excessive or lack quantity of pellets in then burner during the normal
functioning. It’s possible to make some regulations on the equipment combustion. The basket
– burner during the normal combustion should contain combustible from 1/3 till a middle of
its capacity, if necessary, to carry on to some regulations, please follows the following points :
a.
To check the equipment functioning and check if in the burner basket, the pellets
accumulate till the complete fill up of its or if the burner basket emptied till the flame
light off.
b.
Push several times the button
3(SET)
to visualize on the top part of the display
ut40
c.
Push several times the button
1
to visualize on the lower part of the display the num.
33
d.
Push the button 3(SET), the display visualize
“corr”
in the top part and a number in
the lower part.
e.
Employing the button
1
and
2
to modify the number on the lower display as indicated
in the enclosed schedule, to increase the pellets quantity increase the value, to reduce
the pellets quantity reduce the value.
ATTENTION !
We recommend to make these modifications increasing/reducing the
initial
value little by little
( only one number ), checking the equipment functioning for 1 or 2 days
even taking care to keep clean the basket burner, only after this checking period You can
modify again the regulation.
Increase the pellets quantity
Reduce the pellets quantity
9 8 7 6 5 4 3 2 1 0 -1 -2 -3 -4 -5 -6 -7 -8 -9
STAND-BY
The
STAND-BY
status means that when the equipment reach the ambiance temperature set
up, the equipment turn off to start again automatically when a lower temperature is taken.
This is the procedure to follow :
-
Push several times the button
3(SET)
to visualize on the top part of the display
ut04
-
Push several times the button
1
to visualize on the lower part of the display the
numb.99
-
Push the button
3(SET),
the display visualize
“StAn by”
in the top part and
“OFF”
in
the lower part.
-
Program the
°C
(es 1°-2° ecc) the temperature value to activate the
STAND-BY
modality. Program
OFF
to deactivate the
STAND-BY
modality.
-
The stove will function in
STAND-BY
modality so when the temperature ambiance is
reached as set out °C in the preceding point : EX : it’s set up 2° to preceding point and
supposing to have set the equipment to 22°C the modality
STAND-BY
will activate
when the 24°C is reached (22° + 2°) The equipment will light on when the ambiance
temperature will be lower than it set up, in this case 22°C.
IMPORTANT WARNING
•
The stove has to be cold before making every intervention, cleaning or maintenance
operation.
•
TO REMOVE THE PLUG ALWAYS BEFORE MAKE EVERY INTERVENTION
ON THE STOVE
•
During the functioning, in case of problems You can push the Stop button situated on
control panel.
To not break off the functioning removing the plug or pushing the
back button
because this operation block all motors, creating a very difficult exhaust
fumes evacuation.