Page 74 of 80
Maintenance
•
The actuator must be cleaned at regular intervals to remove dust and dirt and inspected for mechanical
damages or wear.
•
Inspect attachment points, wires, piston rod, cabinet, and plug, as well as check that the actuator functions
correctly.
•
To ensure that the pregreased inner tube remains lubricated, the actuator must only be washed down when the
piston rod is fully retracted.
•
The actuator is a closed unit and therefore requires no internal maintenance.
•
In order to maintain a proper performance of the spherical eyes and to increase the resistance against
environmental wear, we strongly recommend that the spherical eyes (ball bearings) mounted on actuators
from LINAK are greased with anticorrosive grease or similar.
Repair
Only an authorised LINAK
®
service centre should repair LINAK actuator systems. Systems to be repaired under
warranty must be sent to an authorised LINAK service centre.
In order to avoid the risk of malfunction, all actuator repairs must only be carried out by an authorised LINAK
Service shop or repairer, as special tools and parts must be used.
If a system is opened by unauthorised personel there is a risk that it may malfunction at a later date.
Main groups of disposal
LINAK’s products may be disposed of, possibly by dividing them into different waste groups for recycling or
combustion.
We recommend that our product is disassembled as much as possible at the disposal and that you try to recycle it.
Chapter 5
Product
Metal scrap
Cable scrap
Electronic scrap
Plastic recycling or
combustion
LA37
X
X
X
X