Liko Uno 102 Instructions For Use Manual Download Page 21

21

7EN150104 Rev. 8  

•  2020

www.hillrom.com  

Applic

ation of c

ommonly used Cleaning / Disin

fect

an

ts on Lik

o pr

oducts

Chemic

al class

Activ

e ingr

edien

t

pH

Cleaner

s / 

Disin

fect

an

t *)

Manuf

actu

rer *)

Ma

y not be used on the  follo

wing it

ems:

Qua

ternar

y ammonium chloride

Didecyl dime

th

yl ammonium chloride = 8.704% 

Alkyl dime

th

yl benz

yl ammonium chloride = 8.19%

9.0 – 10.0 in use

Vir

ex II (256)

Johnson/Div

er

se

y

Foot r

es

t f

or Sabina™ and 

Roll-On™

Qua

ternar

y ammonium chloride

Alkyl dime

th

yl benz

yl ammonium chloride = 13.238%  

 

Alkyl dime

th

yl e

th

ylbenz

yl ammonium chloride = 13.238%

9.5 in use

HB Qua

t 25L

3M

Acceler

at

ed Hy

dr

og

en P

er

oxide

Hy

dr

og

en P

er

oxide 0.1 -1.5%

Benz

ylAlc

ohol: 1-5%

Hy

dr

og

en P

er

oxide 0.1 -1.5%

Benz

ylAlc

ohol: 1-5%

3

Oxivir Tb

Johnson/Div

er

se

y

The lift s

trap

s f

or Golv

o™ 

and ceiling lifts

Phenolic

Ortho-Phen

ylphenol = 3.40% 

Ortho-Benz

yl-par

a-Chlor

ophenol = 3.03

3.1 +/- 0.4 in use

W

ex

cide

W

exf

or

d Lab

s

Bleach

Sodium h

ypochlorit

e

12.2

Dispa

tch

Calt

ech

The lift s

trap

s f

or Golv

o™ 

and ceiling lifts

Alc

ohol

Isopr

op

yl alc

ohol = 70%

5.0 – 7.0

Vir

aguar

d

Veridien

Hand c

on

trols f

or all lifts

Qua

ternar

y ammonium

n-Alkyl dime

th

yl benz

yl ammonium chlorides = 0.105%

n-Alkyl dime

th

yl e

th

ylbenz

yl ammonium chlorides = 0.105%

11.5 - 12.5

CSI

Cen

tral Solutions Inc.

Viking™, Lik

o M220™, Lik

M230™, Uno™, Sabina™,  Golv

o™, 

 

Lik

oLigh

t™, R

oll-On™, 

Lik

or

all™, Multir

all™

Benz

yl-C12-18-alkyldime

th

ylammonium, 

chlorides

Benz

yl-C12-18-alkyldime

th

ylammonium, chlorides (22 %)

2-Pheno

xy

ethanol (20 %)

Tridecylpoly

eth

ylengly

cole

ther (15 %)

Pr

opan-2-ol (8 %)

appr

ox 8.6 in use

Terr

alin Pr

ot

ect

Shülk

e

Foot r

es

t f

or Sabina™ and 

Roll-On™

Or

ganic per

oxide (type E, solid)

Magnesium monoper

oxyph

tala

te he

xah

ydr

at

e (50-100%)

Anionic surf

act

an

t (5-10%)

Nonionic surf

act

an

t (1-5%)

5.3 in use

Dismo

zon Pur

Bode

The lift s

trap

s f

or Golv

o™ 

and ceiling lifts

Ethanol

Hy

dr

og

en per

oxy

de (2.5-10 %)

Laur

yldime

th

ylamine o

xid (0-2.5 %)

Ethanol (2.5-10 %)

7

Anio

xy

-Spr

ay W

S

Anios

Con

trol bo

x f

or all mobile 

lifts

Tr

oclosene sodium

Adipic acid 10-30% Amorphous silic

a < 1%

Sodium T

oluene sulphona

te 5-10 %

Tr

oclosene sodium 10-30 %

4-6 in use

Chlor

-Clean

Gues

t Medic

al L

td

The lift s

trap

s f

or Golv

o™ 

and ceiling lifts

*) Or equiv

alen

t

Summary of Contents for Uno 102

Page 1: ...utmost importance for function and safety when using the lift In this document the person being lifted is referred to as the patient and the person helping them is referred to as the caregiver Product...

Page 2: ...Instructions 4 Definitions 5 Technical Data 5 Dimensions 6 EMC Table 7 Assembly 10 Operation 12 Charging the Batteries 14 Maximum Load 15 Recommended Lifting Accessories 15 Simple Troubleshooting 17...

Page 3: ...line underneath the symbol indicate this product have been placed on the market after 2005 UL Recognized Component Mark for Canada and the United States EFUP Environmental Friendly Usage Period years...

Page 4: ...g accessory hangs vertically and can move freely the lifting accessory is selected appropriately in terms of type size material and design with regard to the patient s needs the lifting accessory is c...

Page 5: ...ont 75 mm 2 9 in twin wheel Rear 75 mm 2 9 in individual wheels fitted with brakes Turning Diameter 1380 mm 54 in Emergency lowering device Mechanical and electrical Lift Interval 1270 mm 50 in Liftin...

Page 6: ...urement Table Measurements in mm Model A Max A Min B B1 B2 B3 C D D1 D2 E F F1 L Max L Min M N O max min max min Uno 102 79 3 77 4 75 8 56 5 54 5 53 0 49 4 36 2 28 7 23 2 42 9 27 2 38 6 22 8 37 4 1 8...

Page 7: ...test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 8 kV contact 2 kV 4 kV 8 kV 15 kV air 8 kV contact 2 kV 4 kV 8 kV 15 kV air Fl...

Page 8: ...is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each freque...

Page 9: ...745 780 810 800 960 GSM 800 900 TETRA 800 IDEN 820 CDMA 850 LTE Band 5 Pulse modulation b 18 Hz 2 0 3 28 870 930 1720 1700 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulatio...

Page 10: ...sired position with the locking handles provided After securing the mast use Pull out rotate to set the locking handles in a downwards position see illustration 2 The lifting height can be set to thre...

Page 11: ...properly 7 Hang the hand control on the handle 8 Reset the emergency stop by turning the button clockwise ON CHARGE BATTERY 9 A Connect the extension cable for the charging cable to the control box B...

Page 12: ...yckt cirkel 46 mm F rgkoder Cirkel R d PMS 185 C Ilustration 100 Svart Locking the Wheels The rear wheels can be locked to prevent rotating and turning The locking unlocking of the wheels is done with...

Page 13: ...he floor Lift correctly Before each lift make sure that the Sling loops at opposite sides of the Sling are at the same height all the Sling loops are fastened securely in to the Slingbar hooks the Sli...

Page 14: ...lights up green when the charger is connected to mains 2 CHARGE lights up yellow constantly during charging and will turn off when charging is completed Charging with the control box internal charger...

Page 15: ...xample a Uno 102 mobile lift which is approved for 175 kg 385 lbs can be equipped with a lifting accessory which is approved for 300 kg 660 lbs In this case the maximum load of 175 kg 385 lbs applies...

Page 16: ...l charger and battery Prod No 2107103 Quick Release Hook Liko Quick Release Hooks is a system for quick change of lifting accessories on Liko s mobile and stationary lifts Uno mobile lift must be equi...

Page 17: ...Check the battery capacity 4 Check that the handcontrol cable is connected correctly 5 Electrical emergency lowering use the operation panel to lower the patient onto a firm surface see chapter Operat...

Page 18: ...gs To help prevent injury and or equipment damage obey these warnings Warning The potential for electrical shock exists with electrical equipment Failure to follow facility protocol could cause death...

Page 19: ...phor and zinc oxide creams can cause permanent stains Remove temporary stains by wiping vigorously with a lightly dampened wiping cloth Cleaning and Disinfection Overview Cleaning and disinfection are...

Page 20: ...TE It is important to remove all visible soil from all areas before continuing to remove non visible soil With a new wiping cloth soaked in an approved cleaner disinfectant use firm pressure to wipe a...

Page 21: ...Golvo and ceiling lifts Alcohol Isopropyl alcohol 70 5 0 7 0 Viraguard Veridien Hand controls for all lifts Quaternary ammonium n Alkyl dimethyl benzyl ammonium chlorides 0 105 n Alkyl dimethyl ethyl...