Liko Uno 102 Instructions For Use Manual Download Page 16

16

7EN150104 Rev. 8  

•  2020

www.hillrom.com

Bag for SlingBars 

 

Prod. No. 2001025

Slingbar Cover Paddy 30 

 

Prod. No. 3607001

(fits Universal SlingBar 350, 450 and 

600 and SlingBar Slim 350).

Leg protector   

 

Prod. No.

 20190029

Adapter 12 mm

Prod. No. 2016504

LikoScale™ device 

for weighing a patient in combination with Uno mobile lifts. 

 

Adapter 12 mm is required.
LikoScale™ 350, Max 400 kg (880 lbs) 

Prod. No. 3156228

 

LikoScale™ 350 is certified according to the 

 

European Directive NAWI 2014/31/EU 

 

(Non-Automatic Weighing Instruments).

LikoScale™ devices only for use in the United states and Canada:

 

LikoScale™ 200, Max. 200 kg (440 Ibs.) 

Prod. No. 3156225

 

LikoScale™ 400, Max. 400 kg (880 Ibs.) 

Prod. No. 3156226.

Contact your Hill-Rom representative for more information.

LikoScale 350

Prod. No. 3156228

Table Charger Housing

excl. charger and battery

Prod. No. 2107103

Quick-Release Hook 

Liko™ Quick-Release Hooks is a system for quick change of lifting accessories on 

Liko’s mobile and stationary lifts. Uno mobile lift must be equipped with the 

 

Q-link 13 in order to be used with the Quick-release Hook.

The Quick-release Hook Universal fits the Universal SlingBar 350, 450 and 600 

(prod. no. 3156074 - 3156076). Quick-release Hook TDM fits the SlingBar Mini 

220 (prod. no. 3156005), Sling Cross-bar 450 and 670 (prod. no. 3156021 and 

3156018) and Universal TwinBar 670 (prod. no. 3156077).

When changing to a sling bar with quick release hook, the lifting height is reduced 

by 33 mm (1.3 in) in comparison with a fixed sling bar.

Contact your Hill-Rom representative for more information.

Quick-Release Hook 

TDM

Prod. No. 3156502

Q-link 13

Prod. No. 3156509

Quick-Release Hook 

Universal

Prod. No. 3156508

X

Y

Z

Battery charger, 

for wallmounting

 

or to use with the 

Table Charger Housing

Prod. No. 2004106

Battery

 

Lead battery (Pb)

Prod. No. 2006106

Summary of Contents for Uno 102

Page 1: ...utmost importance for function and safety when using the lift In this document the person being lifted is referred to as the patient and the person helping them is referred to as the caregiver Product...

Page 2: ...Instructions 4 Definitions 5 Technical Data 5 Dimensions 6 EMC Table 7 Assembly 10 Operation 12 Charging the Batteries 14 Maximum Load 15 Recommended Lifting Accessories 15 Simple Troubleshooting 17...

Page 3: ...line underneath the symbol indicate this product have been placed on the market after 2005 UL Recognized Component Mark for Canada and the United States EFUP Environmental Friendly Usage Period years...

Page 4: ...g accessory hangs vertically and can move freely the lifting accessory is selected appropriately in terms of type size material and design with regard to the patient s needs the lifting accessory is c...

Page 5: ...ont 75 mm 2 9 in twin wheel Rear 75 mm 2 9 in individual wheels fitted with brakes Turning Diameter 1380 mm 54 in Emergency lowering device Mechanical and electrical Lift Interval 1270 mm 50 in Liftin...

Page 6: ...urement Table Measurements in mm Model A Max A Min B B1 B2 B3 C D D1 D2 E F F1 L Max L Min M N O max min max min Uno 102 79 3 77 4 75 8 56 5 54 5 53 0 49 4 36 2 28 7 23 2 42 9 27 2 38 6 22 8 37 4 1 8...

Page 7: ...test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 8 kV contact 2 kV 4 kV 8 kV 15 kV air 8 kV contact 2 kV 4 kV 8 kV 15 kV air Fl...

Page 8: ...is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each freque...

Page 9: ...745 780 810 800 960 GSM 800 900 TETRA 800 IDEN 820 CDMA 850 LTE Band 5 Pulse modulation b 18 Hz 2 0 3 28 870 930 1720 1700 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulatio...

Page 10: ...sired position with the locking handles provided After securing the mast use Pull out rotate to set the locking handles in a downwards position see illustration 2 The lifting height can be set to thre...

Page 11: ...properly 7 Hang the hand control on the handle 8 Reset the emergency stop by turning the button clockwise ON CHARGE BATTERY 9 A Connect the extension cable for the charging cable to the control box B...

Page 12: ...yckt cirkel 46 mm F rgkoder Cirkel R d PMS 185 C Ilustration 100 Svart Locking the Wheels The rear wheels can be locked to prevent rotating and turning The locking unlocking of the wheels is done with...

Page 13: ...he floor Lift correctly Before each lift make sure that the Sling loops at opposite sides of the Sling are at the same height all the Sling loops are fastened securely in to the Slingbar hooks the Sli...

Page 14: ...lights up green when the charger is connected to mains 2 CHARGE lights up yellow constantly during charging and will turn off when charging is completed Charging with the control box internal charger...

Page 15: ...xample a Uno 102 mobile lift which is approved for 175 kg 385 lbs can be equipped with a lifting accessory which is approved for 300 kg 660 lbs In this case the maximum load of 175 kg 385 lbs applies...

Page 16: ...l charger and battery Prod No 2107103 Quick Release Hook Liko Quick Release Hooks is a system for quick change of lifting accessories on Liko s mobile and stationary lifts Uno mobile lift must be equi...

Page 17: ...Check the battery capacity 4 Check that the handcontrol cable is connected correctly 5 Electrical emergency lowering use the operation panel to lower the patient onto a firm surface see chapter Operat...

Page 18: ...gs To help prevent injury and or equipment damage obey these warnings Warning The potential for electrical shock exists with electrical equipment Failure to follow facility protocol could cause death...

Page 19: ...phor and zinc oxide creams can cause permanent stains Remove temporary stains by wiping vigorously with a lightly dampened wiping cloth Cleaning and Disinfection Overview Cleaning and disinfection are...

Page 20: ...TE It is important to remove all visible soil from all areas before continuing to remove non visible soil With a new wiping cloth soaked in an approved cleaner disinfectant use firm pressure to wipe a...

Page 21: ...Golvo and ceiling lifts Alcohol Isopropyl alcohol 70 5 0 7 0 Viraguard Veridien Hand controls for all lifts Quaternary ammonium n Alkyl dimethyl benzyl ammonium chlorides 0 105 n Alkyl dimethyl ethyl...

Page 22: ...product has an expected service life of 10 years when correctly handled serviced and inspected in accordance with Liko s instructions Transport and Storage During transport or if the lift is not goin...