Liko Uno 102 Instructions For Use Manual Download Page 15

15

7EN150104 Rev. 8  

•  2020

www.hillrom.com  

* this product is also available in a version with Quick-Release Hook.

Universal SlingBar 350*

 

Prod. No. 3156074

Max. 300 kg (660 lbs)

Universal SlingBar 450*

 

Prod. No. 3156075

Max. 300 kg (660 lbs)

Universal SlingBar 600*

 

Prod. No. 3156076

Max. 300 kg (660 lbs)

Universal TwinBar 670*

 

Prod. No. 3156077

Max. 300 kg (660 lbs)

Universal SideBars 450

 

Prod. No. 3156079

including bag

Max. 300 kg (660 lbs)

Sling Cross-bar 450*

 

Prod. No. 3156021

Max. 300 kg (660 lbs) 

 

(Adapter 12 mm, prod. no. 2016504 required)

Sling Cross-bar 670*

 

Prod. No. 3156018

Max. 300 kg (660 lbs) 

 

(Adapter 12 mm, prod. no. 2016504 required)

Different maximum loads may apply to different products on the assembled lift unit: lift, sling bar, sling and any other accessories 

used. For the assembled lift unit, the maximum load is always the lowest maximum load rating for any of the components. For 

example, a Uno 102 mobile lift which is approved for 175 kg (385 lbs) can be equipped with a lifting accessory which is approved 

for 300 kg (660 lbs). In this case, the maximum load of 175 kg (385 lbs) applies to the assembled lift unit.

Study the markings on the lift and lifting accessory or contact your Hill-Rom representative if you have any questions.

Maximum Load

Recommended Lifting Accessories

 

 Using lifting accessories other than those approved can entail a risk.

When changing sling bar or other lifting accessories, the highest possible lifting height of the lift is affected. Before changing 

lifting accessories you should always ensure that the lift, after change, can fulfil the desired lifting height in order to manage 

the lifting situations for which the lift is to be used. For additional guidance in selecting a sling, study the instruction for use 

for the respective sling models. There you will also find guidance for combining Liko™ sling bars with Liko slings.

Contact your Hill-Rom representative for advice and information on Liko’s product range.

Summary of Contents for Uno 102

Page 1: ...utmost importance for function and safety when using the lift In this document the person being lifted is referred to as the patient and the person helping them is referred to as the caregiver Product...

Page 2: ...Instructions 4 Definitions 5 Technical Data 5 Dimensions 6 EMC Table 7 Assembly 10 Operation 12 Charging the Batteries 14 Maximum Load 15 Recommended Lifting Accessories 15 Simple Troubleshooting 17...

Page 3: ...line underneath the symbol indicate this product have been placed on the market after 2005 UL Recognized Component Mark for Canada and the United States EFUP Environmental Friendly Usage Period years...

Page 4: ...g accessory hangs vertically and can move freely the lifting accessory is selected appropriately in terms of type size material and design with regard to the patient s needs the lifting accessory is c...

Page 5: ...ont 75 mm 2 9 in twin wheel Rear 75 mm 2 9 in individual wheels fitted with brakes Turning Diameter 1380 mm 54 in Emergency lowering device Mechanical and electrical Lift Interval 1270 mm 50 in Liftin...

Page 6: ...urement Table Measurements in mm Model A Max A Min B B1 B2 B3 C D D1 D2 E F F1 L Max L Min M N O max min max min Uno 102 79 3 77 4 75 8 56 5 54 5 53 0 49 4 36 2 28 7 23 2 42 9 27 2 38 6 22 8 37 4 1 8...

Page 7: ...test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 8 kV contact 2 kV 4 kV 8 kV 15 kV air 8 kV contact 2 kV 4 kV 8 kV 15 kV air Fl...

Page 8: ...is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each freque...

Page 9: ...745 780 810 800 960 GSM 800 900 TETRA 800 IDEN 820 CDMA 850 LTE Band 5 Pulse modulation b 18 Hz 2 0 3 28 870 930 1720 1700 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulatio...

Page 10: ...sired position with the locking handles provided After securing the mast use Pull out rotate to set the locking handles in a downwards position see illustration 2 The lifting height can be set to thre...

Page 11: ...properly 7 Hang the hand control on the handle 8 Reset the emergency stop by turning the button clockwise ON CHARGE BATTERY 9 A Connect the extension cable for the charging cable to the control box B...

Page 12: ...yckt cirkel 46 mm F rgkoder Cirkel R d PMS 185 C Ilustration 100 Svart Locking the Wheels The rear wheels can be locked to prevent rotating and turning The locking unlocking of the wheels is done with...

Page 13: ...he floor Lift correctly Before each lift make sure that the Sling loops at opposite sides of the Sling are at the same height all the Sling loops are fastened securely in to the Slingbar hooks the Sli...

Page 14: ...lights up green when the charger is connected to mains 2 CHARGE lights up yellow constantly during charging and will turn off when charging is completed Charging with the control box internal charger...

Page 15: ...xample a Uno 102 mobile lift which is approved for 175 kg 385 lbs can be equipped with a lifting accessory which is approved for 300 kg 660 lbs In this case the maximum load of 175 kg 385 lbs applies...

Page 16: ...l charger and battery Prod No 2107103 Quick Release Hook Liko Quick Release Hooks is a system for quick change of lifting accessories on Liko s mobile and stationary lifts Uno mobile lift must be equi...

Page 17: ...Check the battery capacity 4 Check that the handcontrol cable is connected correctly 5 Electrical emergency lowering use the operation panel to lower the patient onto a firm surface see chapter Operat...

Page 18: ...gs To help prevent injury and or equipment damage obey these warnings Warning The potential for electrical shock exists with electrical equipment Failure to follow facility protocol could cause death...

Page 19: ...phor and zinc oxide creams can cause permanent stains Remove temporary stains by wiping vigorously with a lightly dampened wiping cloth Cleaning and Disinfection Overview Cleaning and disinfection are...

Page 20: ...TE It is important to remove all visible soil from all areas before continuing to remove non visible soil With a new wiping cloth soaked in an approved cleaner disinfectant use firm pressure to wipe a...

Page 21: ...Golvo and ceiling lifts Alcohol Isopropyl alcohol 70 5 0 7 0 Viraguard Veridien Hand controls for all lifts Quaternary ammonium n Alkyl dimethyl benzyl ammonium chlorides 0 105 n Alkyl dimethyl ethyl...

Page 22: ...product has an expected service life of 10 years when correctly handled serviced and inspected in accordance with Liko s instructions Transport and Storage During transport or if the lift is not goin...