LD30x
7 Set up procedure
For better understanding the following sections “7.1 Basic settings” and “7.2
Operational parameters” explain settings related to the display only model
(LD300). Model-specific settings for analogue output model (LD301),
Preselections model (LD302) and Serial Link model (LD303) will be explained
separately under sections from “7.3 Model LD301: additional settings for the
analogue output“ to “7.5 Model LD303: additional settings for the serial
interface“.
7.1 Basic settings
Customarily these settings have to be carried out one time only upon the very
first use of the unit. The basic set-up selects the desired operation mode of the
unit, the input characteristics PNP/NPN and the desired brightness of the LED
display.
NOTE
To access the Basic Set-up press the
ENTER
and
SET
keys simultaneously for at
least 3 seconds.
Menu
Setting range
Default
tYPE
Operation Mode
rPm
Tachometer, frequency meter (see section “7.2.1 RPM,
operation as tachometer or frequency counter“).
rPm
Baking time / processing time indicator (see section
“7.2.2 Time, display of baking or processing time
(reciprocal speed)“).
timE
Timer, Stopwatch (see section “7.2.3 Timer,
Stopwatch“).
timEr
Counter for position or event (see section “7.2.4
Count, Counter mode“).
Count
Speed calculation from differential transition time
(see section “7.2.5 Speed from differential time
between a Start and a Stop input“).
SPEEd
CHAr
Switching characteristics of the inputs
PnP
NPN, switch to “-“
nPn
PNP, switch to “+“
PnP
briGht
Brightness of the LED display
20%, 40%, 60%,
80%, 100%
100%