LD30x
7.2 Operational parameters
7.2.1 RPM, operation as tachometer or frequency counter
(Input A = frequency input, Input B not in use)
Menu
Setting Range
Default
FrEqu
Frequency
Set a typical operating frequency for your
application.
1 Hz to
25 000 Hz
1000
diSPL
Display Value
Set the value you would like to see on your display
with above frequency at the input.
1 ... 99999
1000
dPoint
Decimal Point
Select the desired position as shown in the display.
000.000
no decimal point
000000
decimal point at position 1
00000.0
---->
decimal point at position 5
0.00000
WAit
Wait Time
Define a “waiting time“, this is the time expressed in
seconds that the unit will wait from one input pulse
to the next, before it sets the display to zero. When
you enter “0“, the unit will wait forever and show the
last result until it receives the next input.
0.1 … 99.9 sec
1.0
The setting of this parameter automatically limits the minimum
input frequency correspondingly. With “Wait” set to e.g. 0.1 sec.
the unit will respond to frequencies > 10 Hz only and all lower
frequencies will just display 0.
FiltEr
Average Filter
Selectable average filter to suppress unstable display
with unsteady input frequencies.
OFF
No filtering
OFF
2, 4, 8, 16 = number of floating average cycles.
16
NOTE
LD301 model also provides a signed speed display with the +/- sign changing
according to the direction of rotation (see section “7.3 Model LD301: additional
settings for the analogue output“).
MAN LD30x E 1.0.odt
Set up procedure
16 of 40