LD30x
The following operational parameters provide setting of the communication
profile:
Menu
Setting Range
Default
S-tim
Serial Timer
Setting 0.000 allows manual activation of a serial data
transmission at any time. All other settings specify the
cycle time for automatic transmission (provided the
S-
mod
item is set to "Printer-mode" (see the next item
and on page 29).
0.000;
0.010 …
9.999 sec
0.1 sec
Between two transmission cycles the unit will allow a
pause depending on the baud rate. The minimum cycle
times for timer transmissions are shown in the table.
Baud
Rate
Minimum Cycle Time [msec]
600
384
1200
192
2400
96
4800
48
9600
24
19200
12
38400
6
S-mod
Serial Mode
PC
Operation according to communication profile (see
section “7.5.1 PC-Mode“ on page 27).
PC
Transmission of string type 1 (see section “7.5.2
Printer-Mode” on page 29).
Print1
Transmission of string type 2 (see section “7.5.2
Printer-Mode“ on page 29).
Print2
S-CodE
Serial Register-Code
Specifies the register code of the data to be
transmitted. The most important register codes are the
actual display value and the serial Set/Reset command
code.
Register
S-Code
ASCII
Actual display value
101
: 1
Activate SET /RESET
60
6 0
100
...
120
101