LD30x
7.2.2 Time, display of baking or processing time (reciprocal speed)
(Input A = frequency input, Input B not in use)
Menu
Setting Range
Default
diSfor
Display Format
Select between seconds, minutes, minutes and
seconds or minutes with two decimal positions. This
will also automatically set your decimal point to the
proper place.
SEC
Seconds
SEC
Minutes
min
Minutes and seconds
mi-SE
Minutes with two decimal positions
min.00
FrEqu
Frequency
Set a typical operating frequency for your
application.
1 Hz to
25 000 Hz
100
diSPL
Display Value
Set the value you would like to see on your display
with above frequency at the input.
1 ... 999999
100
WAit
Wait Time
Define a “waiting time“, this is the time in seconds
that the unit will wait from one input pulse to the
next, before it sets the display to zero. When you
enter “0“, the unit will wait forever and show the last
result until it receives the next input.
0.1 … 99.9 sec
5.0
The setting of this parameter automatically limits the minimum
input frequency correspondingly. With “Wait” set to e.g. 0.1 sec.
the unit will respond to frequencies > 10 Hz only and all lower
frequencies will just display 0.
FiLtEr
Average Filter
Selectable averages filter to suppress unstable display
with unsteady input frequencies.
OFF
No filtering.
OFF
2, 4, 8, 16 = number of floating average cycles.
16
MAN LD30x E 1.0.odt
Set up procedure
17 of 40