7.5 Model LD303: additional settings for the serial interface
The basic set-up menu contains the main parameters for configuration of the
serial interface.
Menu
Setting Range
Default
S-Unit
Serial Unit Number
You can assign any address number between 11 and
99 to your unit.
The address must not contain a “0“ because such
numbers are reserved for collective addressing.
0 ... 99
11
S-Forn
Serial data format
7 E 1
The first character indicates the number of Data Bits.
The second character specifies the Parity Bit (“even”
or “odd” or “none”)
The third character indicates the number of Stop
Bits.
7 E 1
7 E 2
7 0 1
7 0 2
7 no 1
7 no 2
8 E 1
8 0 1
8 no 1
8 no 2
S-bAUd
Baud rate
9600
The following baud rates can be selected.
9600
4800
2400
1200
600
19200
38400