LD30x
7.2.5 Speed from differential time between a Start and a Stop input
Input A operates as a start input and input B operates as a Stop input. The
differential time between start and stop will be converted into the speed of the
passing object.
Menu
Setting Range
Default
timE
Time
Enter a typical delay time which you expect between
the start and stop signals.
000.001
…
999.999 sec
1.000 sec
diSPL
Display Value
Enter the speed you would like to see in the display
when an object passes within above time.
000.001
…
999.999
1.000
dPoint
Decimal Point
Select the desired position as shown in the display.
000.000
no decimal point
000000
one decimal position
00000.0
---->
five decimal positions
0.00000
WAit
Wait Time
How long should the last result remain in the display
before it returns to zero? Set the desired waiting
time. With setting “0” the display will freeze and wait
until to the next measuring cycle.
0.00
...
9.99
1.00
7.2.6 Linearisation points
The linearisation points will only appear with "RPM" or "Count" operation modes
when Linearisation is enabled.
Menu
Setting Range
Default
P01_X
Linearisation point 1
X value of the first interpolation point.
-199999
... 999999
999999
P01_Y
Linearisation point 1
Y value of the first interpolation point.
-199999
... 999999
999999
…
…
P16_X
Linearisation point 16
X value of the 16. interpolation point.
-199999
... 999999
999999
P16_Y
Linearisation point 16
Y value of the 16. interpolation point.
-199999
... 999999
999999
For more details about linearisation please refer to section “8.1 Linearisation“ on
page 30.
MAN LD30x E 1.0.odt
Set up procedure
20 of 40