Incoming as well as outgoing wires and wires for extra low voltages (ELV) must
be separated from dangerous electrical cables (SELV circuits) by using double or
increased insulation.
All selected wires and insulations must comply with the provided voltage and
temperature ranges. Furthermore all country- and application-specific standards
which are relevant for structure, form, and quality of the wires, must be
ensured. Indications about the permissible wire cross-sections for wiring are
described in the “9 - Technical Specifications“ section on page 39.
Before starting the unit for the first time it must be ensured that all connections
and wires are firmly plugged in and secured to the screw terminals. All terminals
(including unused terminals) must be fastened by turning the relevant screws
clockwise up to the end position.
Overvoltages at the connections must be limited to values in accordance to the
overvoltage category II.
For placement, wiring, environmental conditions as well as shielding and
earthing/grounding of the supply lines you must comply with the general
standards stated for the industrial automation industry and the specific
shielding instructions provided by the manufacturer.
3.3 Mounting the display unit on the IFS-10 safety unit
The mounting of the IFS-10-PM programming and display unit is performed by
simply plugging it into the IFS-10 safety device. Via the 8-pin connector
3
both
units are electrically connected. A mechanical polarity protection
2
ensures that
the device cannot be plugged incorrectly. Neodymium magnet
1
ensures a safe
mechanical connection.
IFS-10-PM rear view
Figure 2
1 Neodymium Magnet
Neodymium Magnet for safety mounting
2 Polarity protection
Mechanical polarity protection
3 8-pin male connector
For electrical connection (see the “4.1 8-pin
male connector” section on page 14).
MAN IFS-10-PM EN 1.1.odt
3 – Technical features
12/44
1
2
3