SCS1620 Product Manual
15.00.032 Rev. B
Page 17
The Modem is initially set up using the
setup
setup
setup
setup
program (see Section 5.3) of the
system. Refer to Section 7 for Modem Installation instructions, if installing a
modem into a working SCS1620 system.
3.7
Power Manager Port
The Power Manager port is configured as
Device Port 17
, and operates like the
other DEVICE ports, except that its physical interface is a DB9F serial connector.
The Power Manager port is intended for the Lightwave PCU8 Power Control Unit.
The default communication parameters for the POWER MANAGER port are:
•
9600 baud,
•
8 data bits,
•
1 stop bit,
•
No parity,
•
Xon/Xoff flow control, and
•
port type of DTE
.
The Power Manager Port, like the DEVICE ports, can be configured for baud
rates of 2400 - 115.2K baud, and DTE or DCE. The data word must be 8/none/1
and employ Xon / Xoff flow control.