INSTALLATION & SERVICE MANUAL – FLEXSTEP V2– UK VERSION
1.7
Liftup A/S
Hagensvej 21| DK-9530 Støvring | Denmark |
T:
+45 96 86 30 20 |
M:
[email protected] | www.liftup.dk | CVR DK-1015 3964
56
8.4
Circlips for steps
Remove the circlips and washers from
the two girders on all steps.
Carefully remove the girders from the
steps, while taking care of the wires.
Please note it is important to hold the
steps in fixed position to avoid the
wires to be cut when the girders are
removed.
8.5
Screws for handrails
Remove all the M5 screws at the
handrails and remove the handrails.
When the screws are removed, be
careful to keep the steps and girder in
fixed position to avoid the wires to be
cut.
Now you can easily move the
FlexStep V2 parts to the desired
installation site.
M5 screws
Circlips