INSTALLATION & SERVICE MANUAL – FLEXSTEP V2– UK VERSION
1.7
Liftup A/S
Hagensvej 21| DK-9530 Støvring | Denmark |
T:
+45 96 86 30 20 |
M:
[email protected] | www.liftup.dk | CVR DK-1015 3964
41
3.
In the Stroke area, set the value of actuators:
o
Platform Lifting height , in mm (see NOTE)
o
Stair Position, in mm (see NOTE)
4.
Push the “Write system parameters to device”.
Now the system is ready to run, please remember to check that all settings are as
expected.
NOTE: Remember to deduct approx. 70 mm to your settings as the platform is approx. 70
mm thick.
IMPORTANT!
After programming the system must be calibrated by pushing the “lift down” button
until the platform is positioned at lower landing.
3
4
2