40
5
Setting of Lifting Height and Stair Position
5.1
Definition
All FlexStep V2 are delivered with 2 programmable height settings.
1
st
programmable height setting (Platform Lifting Height) is the position where the
platform will stop when it reaches the top landing.
2
nd
programmable height setting (Stair Position) (can be the same as the Platform lifthing
height) is the position of the top step when the FlexStep V2 is in Staircase position.
According to your order confirmation the lift is tested and set to your specified heights
but can be modified, if adjustment is needed.
5.2
Settings of the 2 stops using the “Liftup Service Tool”
The Liftup Service Tool must be installed on a PC(*) (Laptop) with a USB output.
1.
Place the USB cable into the PC and into the USB plug of the Master control board
(102352) on the FlexStep V2 (RH side of the lift).
2.
Start the Liftup Service Tool on PC (make sure you know the name of the COM port,
see Annexe to see how). You should see the “Connected” box with green
background (see below, USB detected on COM 4)
(*) PC must be Windows 7 or newer. Windows XP is usable but requires special drivers.
Staircase top stop is the same as
platform top stop
Staircase top stop is lower than
platform top stop (= 2 top stops)