INSTALLATION & SERVICE MANUAL – FLEXSTEP V2– UK VERSION
1.7
Liftup A/S
Hagensvej 21| DK-9530 Støvring | Denmark |
T:
+45 96 86 30 20 |
M:
[email protected] | www.liftup.dk | CVR DK-1015 3964
29
PRIMARY Control board
(102352)RH side mounted
3.3
Control Board Jumpers JP1
IMPORTANT!
Remove all jumpers to reactivate all safety functions. (Except “Ignore GO”)
Jumpers and LED is only valid on PRIMARY control board – right hand side.
Description
Action if jumper is ON.
(ONLY on PRIMARY Control Board)
Under Pan SW.
Ignore safety switches
IR Platform
Ignore IR error upper step
Lower Gate SW.
Ignore ramp switch
IR Stairs
Ignore IR error stairs and girder squeeze protection
Upper Gate SW.
Ignore safety barrier switch
Ignore GO
Allows auto return and soft stop
Jumpers
PRIMARY Control board (102352)
RH side